Benchreads

How to become a sustainability consultant · Module 01 of 6 · 11 minutes

Measuring emissions: GHG Protocol, Scope 1 to 3

How a greenhouse gas inventory under the GHG Protocol is structured, what Scope 1, 2 and 3 mean, why there are two methods for electricity and where estimates are sufficient.

Anyone who wants to reduce emissions must first measure them. Almost all companies use the Greenhouse Gas Protocol for this. The inventory sounds technical, but it determines everything that follows: which targets are set, which measures pay off and what goes into the sustainability report. This module explains how such an inventory is built and where the typical pitfalls lie.

01The standard

The Greenhouse Gas Protocol was developed by the World Resources Institute and the World Business Council for Sustainable Development. The Corporate Standard was published in 2001 and in a revised version in 2004. It sets out how companies define the boundaries of their emissions, calculate them and report them. A separate standard for Scope 3 emissions followed in 2011, and guidance for Scope 2 in 2015.

It covers not only CO2 but all seven greenhouse gases of the Kyoto Protocol, including methane and nitrous oxide. They are converted into CO2 equivalents using their global warming potential. The first step is setting the boundary: which entities and sites belong in the inventory? For this, the GHG Protocol allows an equity share approach or a control approach.

02Three scopes

Scope 1 covers direct emissions from sources that the company owns or controls: boilers, process plants, its own vehicles. Scope 2 covers indirect emissions from purchased energy, above all electricity, heat and steam. Scope 3 covers all other indirect emissions in the value chain.

The Scope 3 Standard divides these emissions into 15 categories, eight upstream and seven downstream. Upstream categories include purchased goods and services, capital goods, transport and business travel. Downstream categories include transport to the customer, the use of the products sold and their disposal.

  • Scope 1: direct emissions from own sources
  • Scope 2: purchased energy
  • Scope 3 upstream: eight categories, such as purchased goods
  • Scope 3 downstream: seven categories, such as use of sold products

03Two methods for electricity

Since the Scope 2 Guidance of 2015, companies have reported their electricity emissions in two ways. The location-based method uses the average emission factor of the grid from which the electricity is drawn. The market-based method takes into account which electricity the company has bought under contract, for example through guarantees of origin or direct supply contracts with wind and solar farms.

The difference can be large. A company that buys green electricity certificates can be close to zero on a market basis but still have considerable emissions on a location basis. Consultants should know both figures and ask whether the contracts trigger additional renewable generation or merely reallocate existing generation.

04Why Scope 3 matters so much

In many industries, Scope 3 accounts for the largest part of the inventory. For a carmaker, emissions from the use of the vehicles dominate; for a food retailer, emissions from suppliers’ farming; for a bank, financed emissions. Anyone who only looks at Scope 1 and 2 often overlooks the most important lever.

At the same time, Scope 3 is the hardest to measure. It often starts with spend-based estimates, that is, euros spent multiplied by average factors per product group. This shows the big blocks but does not measure any improvement at the supplier. For the most important categories, primary data is therefore worthwhile, such as product-specific emission values from the largest suppliers.

05Building an inventory pragmatically

A proven approach: first calculate Scope 1 and 2 properly from energy and fuel data, then roughly estimate all 15 Scope 3 categories, identify the largest categories and improve data quality there. Often a few categories account for most of the emissions, in line with the Pareto principle.

A fixed base year against which later years are compared is important, as is a rule for when it is recalculated, for example after major acquisitions. The inventory should also receive the same care as financial figures: documented methods, traceable sources and an assurance review if it is reported externally.

Example

A machinery maker discovers its biggest lever

A machinery maker calculates a complete inventory for the first time. Scope 1 and 2 come to 40,000 tonnes of CO2 equivalents, mainly from gas for paint shops and from electricity. The rough Scope 3 estimate comes to around 1.2 million tonnes, of which about three quarters come from the use of the machines sold over their lifetime and one fifth from purchased steel.

The strategy shifts: instead of only converting its own paint shop, the company makes the energy efficiency of its machines a development goal and agrees emissions data and targets with its three largest steel suppliers. The example is invented and the figures are illustrative.

Typical mistakes

  • Looking only at Scope 1 and 2.
  • Reporting market-based electricity emissions without looking at the location-based figures.
  • Presenting spend-based estimates as a measurement of improvements.
  • Failing to set a fixed base year and a rule for recalculations.

+Exercise

Take the sustainability report of an industrial company and note how its emissions are split across Scope 1, 2 and 3. Which three Scope 3 categories are the largest, and how were they calculated?

+Self-check

QuestionWhat distinguishes Scope 1, 2 and 3?

Scope 1 covers direct emissions from own sources, Scope 2 emissions from purchased energy, and Scope 3 all other emissions in the value chain.

Start the test: 30 questions

QuestionHow many categories does the GHG Protocol divide Scope 3 into?

Into 15 categories, eight upstream and seven downstream.

Start the test: 30 questions

QuestionWhat distinguishes the location-based method from the market-based method?

The location-based method uses the average of the electricity grid; the market-based method uses the electricity bought under contract, for example through guarantees of origin.

Start the test: 30 questions

Module test

30 questions with instant feedback and explanations. At 80 percent or more, you have it.

Start the test

+Keep learning

Amazon links on English pages carry no affiliate tag.

How to cite this page

APA (7th edition)

Benchreads. (2026). Measuring emissions: GHG Protocol, Scope 1 to 3. Learning path: How to become a sustainability consultant. Retrieved 25 November 2026, from https://benchreads.com/en/learning-paths/become-a-sustainability-consultant/measuring-emissions-ghg-protocol-scope-1-to-3/

Benchreads is a secondary source. For academic work, also cite the original sources named in the text. You are welcome to link to this page in course materials.

Last updated: 25 November 2026. Carefully researched, but without guarantee. Not legal, tax or investment advice. Disclaimer